Electrical
·
Supply
Voltage 11.5 to 16.0V DC (full RF performance)
·
Reverse
polarity input protection provided on the supply
·
Supply
Current operating
3.5A typical @ 13.8V on high power
setting
1.6A typical @ 13.8V on low power
setting
·
Supply
Current quiescent (RF shutdown) mode <1A
·
Frequency
range 1450-1650MHz (L-band, 2MHz steps)
·
Minimum
channel spacing 4MHz (6MHz recommended)
·
RF
output power 50mW to 1W adjustable
Outputs
·
1
RF output (L-band)
Typical error corrected payload
data rate of 2Mbps
Communications
·
2 HDLC
interfaces, full duplex with 2 way synchronous clocks, up to 8Mbps (can be software configured as 1 HDLC and 1
ARCNET, up to 10Mbps)
·
1
CAN bus interface, up to 1Mbps as standard
·
1
RS232 interface, up to 57.6kbps
Diagnostics
· 2 internal diagnostic temperature
sensors
· 2 internal RF power sensors (forward and
reverse)
|
Application
·
High
data rate continuous telemetry transmitter
Connection
Definition
·
Chassis
connector AS2 12-35PN
·
RF
connector 50ohm SMA socket
·
For
pinout information please consult our Technical Consultancy Department
Mechanical
· Case material magnesium alloy, chromate
converted and painted with black epoxy polyester paint
· Weight approximately 508g
· Vibration isolation is recommended
Recommended
Service Interval
1 year
Environmental
· Splash resistant to standard motorsport
fluids
· Lid is sealed to the case, all
through-case fixings sealed with silicone sealant, sealed motorsport
connectors
· Maximum humidity 100%
· Minimum operating temperature 0°C
· Internal temperature not to exceed 70°C
as measured on the temperature diagnostic, if necessary forced air cooling
should be applied
· Storage temperature -10 to 85°C
· Vibration 100 to 1000Hz, all axes, 24hrs
|