The EDR-400 is a compact, self-contained data logger developed specially for on-board racing applications.

 

The unit provides 42 direct inputs, and additional inputs via CAN-linked sensor interface units.

 

The unit comes with 1Gbytes integrated logging memory, GPS and integrated 230 kbps telemetry option.

 

For compatibility with existing units and expansion potential, please refer to the application notes.

 

 

Electrical

 

·       Supply Voltage 7.5 to 16.0V DC

·       Supply Voltage not to exceed 17V continuous (the unit is protected against transients and reverse polarity)

·       TAGOS 32-bit Real Time Operating System

·       Internal Data logging memory capacity 1Gbytes

·       Maximum logging data rate 100Kbytes/sec

·       Up to 200 channels can be logged.

·       Maximum sample rate 1KHz per channel

·       GPS with 4Hz update rate (maximum)

 

Mechanical

    

·      Case material Aluminium, anodised black

·      Weight 550g (605g including telemetry option)

 

Application     

 

·       General data logging and control

 

Other features

·       ATLASLite supplied with each unit

·       One System Monitor configuration software licence supplied per team

 

Ordercodes

·       EDR-400 (Base unit) O 030 071 010 000

·       EDR-400T (with telemetry option) O 030 071 010 001

 

 

Connection Definition

 

·       Integral, sealed, military standard connectors

 

Environmental

 

·      Splash resistant to standard motorsport fluids

·      Lids sealed with O rings and screws sealed with silicone rubber

·      Maximum humidity 100%

·      Minimum operating temperature -10°C

·      Internal temperature not to exceed 70°C as measured by internal diagnostic sensors

·      Storage temperature -10 to +85°C

·      Vibration 100 to 1000Hz, all axes, 24hrs

 

Electro Magnetic Compatibility

 

·      Complies with the essential protection requirements of EMC Directive 2004/108/EC

 

Telemetry Option

 

·      Integrated 902 to 928MHz FHSS transceiver

·      Peak data rate 230kbps (19.2 to 230kbps settings)

·      Maximum 1W output power (programmable)

·      Car antenna O 030 065 014 000

·      Pit antenna O 030 065 015 000        

·      CBR-400 Modem Receiver O 030 052 012 000

 

 


 

 

 

 

Sensor Inputs

 

·        7 DHE Speed Sensors

·        22 Analog (0 to 5V)

·        4 Pt1000 temperature sensors (programmable as analogs)

·        3 NTC temperature sensors (programmable as analogs)

·        3 switch inputs (programmable as analogs)

·        2 K type thermocouples

·        Lap Trigger

 

Outputs

 

·      2 H-Bridges or 4 High/Low side drivers (programmable)

·      3 Low side drivers

·      External sensor supplies

·      PCU-6 drivers (requires 2 High/Low side drives and the 3 Low side drivers)

 

Communications

 

·      1 Ethernet (up to 100Mbps)

·      2 CAN 2.0B bus (up to 1Mbps)

·      1 RS232 (up to 230kbps)

·      1 bidirectional telemetry option (19.2 to 230kbps settings)

 

Data logging

 

·      1 Gbyte logging memory

 

Diagnostics

 

·      Sensor readings are checked for out of range and open circuit

·      The following internal parameters are monitored:

 

 

Board temperatures

Unit supply voltages

Bridge/High side currents

HS/LS output status

GPS system status

 

 

 

 

 

 


 

 

Description

Order Code

EDR-400T (with telemetry option)

EDR-400 (Base unit)

O 030 071 010 001

O 030 071 010 000

 

McLAREN TECHNOLOGY CENTRE
CHERTSEY ROAD, WOKING
SURREY GU21 4YH, UNITED KINGDOM

T: +44 (0) 1483 261400
F: +44 (0) 1483 261402
W:www.mclarenelectronics.com

ASIAN REP:    TOKYO R&D CO. LTD
T: +81 (0) 46 224 6729
F: +81 (0) 46 224 6725

USA Office:    McLaren Electronics Incorporated
T: +1 704 660 3181
F: +1 704 660 8829

close